MHCS622-V/G

Heating and Cooling Vacuum/Gas Stage MHCS622

Heating and Cooling Vacuum/Gas Stage MHCS622
MicrOptik’s MHCS622-V/G series are temperature controlled heating/cooling and vacuum/gas tight stages. MHCS622-V/G stages are ideal instruments for optical thermal microscopy and spectroscopy applications as well as for other general applications where a broad temperature range is required. MHCS622-V/G are easy to incorporate in any complex high-tech setup. The MHCS622-V/G stages offer the best solution for Geological, Fluid Inclusion, Semiconductor, Photovoltaic, or other Materials Science applications.

MicrOptik has developed a new MHCS622-V/G series of Heating and Cooling Stage with a wide temperature range to operate under vacuum and gas tight Environments.

Features

Vacuum or Gas Tight Environments
Wide temperature range
Programmable temperature controller
Software or Manual control
Wide range of viewing apertures
Removable cover for easy sample access
Horizontal and vertical mounting
High precision and high resolution t° measurement and control
Water cooling frame
Vacuum port, gas port, vacuumed 4/6 or 8 pins electrical feedthrough

MicrOptik’s MHCS622-V/G stages are developed for vacuum or/and gas tight applications with temperature range  -190°C to 600°C. MHCS622-V/G stages are supplied with a high precision MTDC600 programmable temperature controller. MTDC600 temperature controller can be operated by Software or Manually. It makes the system more adaptive and flexible. For applications below ambient temperature Liquid Nitrogen Cooling System LN2-SYS is provided.

The MTDC600 is a high performance temperature controller with resolution and accuracy 0.10C. The controller MTDC600 has a built-in power supply and can be controlled manually or through a USB2.0 communication port. Software provides a convenient platform for all possible experiments. PID parameters, temperature limits and control essentials can be easy selected through the relevant menus.

MHCS622-V/G Technical Specification

Temperature Range -190°C to 600°C (Below ambient requires cooling accessories)
Temperature Resolution 0.1°C
Temperature Control Method Switching PID-PID
Temperature Control Sensor RTD
Sample Area 40mm x 40mm (other sample area optional)
Chamber Height Standard 4mm (other up to 20 mm per request)
Sample Viewing Aperture 32mm (other per request )
Minimum Objective Working Distance 6mm (shorter working distance optional)
Electrical feedthrough 4 electrical feed-through (other  per request)

Overall Dimensions

Ask our sale representatives for more information!